Dell PowerVault ME Series Fibre Channel and iSCSI drivers¶
The PVMEFCDriver and PVMEISCSIDriver Cinder drivers allow the
Dell PowerVault ME Series storage arrays to be used for Block
Storage in OpenStack deployments.
System requirements¶
To use the PowerVault ME Series drivers, the following are required:
- PowerVault ME5 Series storage array with I200 or later firmware, or 
- PowerVault ME4 Series storage array with G280 or later firmware 
- iSCSI or Fibre Channel host interfaces 
- Network connectivity between the OpenStack hosts and the array’s embedded management interface 
- The HTTPS protocol must be enabled on the array 
Supported operations¶
- Create, delete, attach, and detach volumes. 
- Create, list, and delete volume snapshots. 
- Create a volume from a snapshot. 
- Copy an image to a volume. 
- Copy a volume to an image. 
- Clone a volume. 
- Extend a volume. 
- Migrate a volume with back-end assistance. 
- Retype a volume. 
- Manage and unmanage a volume. 
Configuring the array¶
- Verify that the array can be managed via an HTTPS connection. HTTP can also be used if - driver_use_sslis set to False in the- cinder.conffile.- Confirm that virtual pools A and B are already present on the array. If they are missing, create them. 
- Edit the - cinder.conffile to define a storage back-end entry for each storage pool on the array that will be managed by OpenStack. Each entry consists of a unique section name, surrounded by square brackets, followed by options specified in a- key=valueformat.- The - pvme_pool_namevalue specifies the name of the storage pool or vdisk on the array.
- The - volume_backend_nameoption value can be a unique value, if you wish to be able to assign volumes to a specific storage pool on the array, or a name that is shared among multiple storage pools to let the volume scheduler choose where new volumes are allocated.
 
- The following - cinder.confoptions generally have identical values for each backend section on the array:- volume_driverspecifies the Cinder driver name.
- san_ipspecifies the IP addresses or host names of the array’s management controllers.
- san_loginand- san_passwordspecify the username and password of an array user account with- manageprivileges
- driver_use_sslmust be set to True to enable use of the HTTPS protocol.
- pvme_iscsi_ipsspecifies the iSCSI IP addresses for the array if using the iSCSI transport protocol
 - In the examples below, two back ends are defined, one for pool A and one for pool B, and a common - volume_backend_nameis used so that a single volume type definition can be used to allocate volumes from both pools.- iSCSI example back-end entries - [pool-a] pvme_pool_name = A volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.iscsi.PVMEISCSIDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage pvme_iscsi_ips = 10.2.3.4,10.2.3.5 driver_use_ssl = true [pool-b] pvme_pool_name = B volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.iscsi.PVMEISCSIDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage pvme_iscsi_ips = 10.2.3.4,10.2.3.5 driver_use_ssl = true - Fibre Channel example back-end entries - [pool-a] pvme_pool_name = A volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.fc.PVMEFCDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage driver_use_ssl = true [pool-b] pvme_pool_name = B volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.fc.PVMEFCDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage driver_use_ssl = true 
- If HTTPS is enabled, you can enable certificate verification with the option - driver_ssl_cert_verify = True. You may also use the- driver_ssl_cert_pathparameter to specify the path to a CA_BUNDLE file containing CAs other than those in the default list.
- Modify the - [DEFAULT]section of the- cinder.conffile to add an- enabled_backendsparameter specifying the backend entries you added, and a- default_volume_typeparameter specifying the name of a volume type that you will create in the next step.- Example of [DEFAULT] section changes - [DEFAULT] enabled_backends = pool-a,pool-b default_volume_type = pvme 
- Create a new volume type for each distinct - volume_backend_namevalue that you added in the- cinder.conffile. The example below assumes that the same- volume_backend_name=pvme-arrayoption was specified in all of the entries, and specifies that the volume type- pvmecan be used to allocate volumes from any of them.- Example of creating a volume type - $ openstack volume type create pvme $ openstack volume type set --property volume_backend_name=pvme-array pvme 
- After modifying the - cinder.conffile, restart the- cinder-volumeservice.
Driver-specific options¶
The following table contains the configuration options that are specific to the PowerVault ME Series drivers.
| Configuration option = Default value | Description | 
|---|---|
| 
 | (List of String) List of comma-separated target iSCSI IP addresses. | 
| 
 | (String) Pool or Vdisk name to use for volume creation. | 