Configuration¶
To enable the ironic-prometheus-exporter to collect the sensor data from
Ironic, it’s necessary to enable some configuration parameters in the
ironic.conf.
Below you can see an example of the required configuration, the table
Configuration options for the ironic-prometheus-exporter
in Ironic shows all the available configuration options.
Example of configuration
[oslo_messaging_notifications]
driver = prometheus_exporter
transport_url = fake://
location = /opt/stack/node_metrics
[sensor_data]
send_sensor_data = true
interval = 600
[metrics]
backend = collector
Section |
Setting |
Value |
Description |
Required |
|---|---|---|---|---|
sensor_data |
send_sensor_data |
true |
Enable sending sensor data message via the notification bus. |
|
sensor_data |
interval |
600 ( |
Seconds between conductor sending sensor data message via the notification bus. |
No |
sensor_data |
enable_for_undeployed_nodes |
false ( |
When set to true, the conductor will collect sensor
information from all nodes when sensor data collection is
enabled via the |
No |
metrics |
backend |
collector |
When set to collector, the metrics system collects metrics
data and saves it in memory for use by the running
application and emits to the configured
|
|
oslo_messaging_notifications |
driver |
prometheus_exporter |
The Drivers(s) to handle sending notifications. |
|
oslo_messaging_notifications |
transport_url |
fake:// |
A URL representing the messaging driver to use for notifications. If not set, we fall back to the same configuration used for RPC. |
|
oslo_messaging_notifications |
location |
<dir_path> |
Directory where the files will be written. |
|
Note
After doing the modifications in the ironic.conf don’t forget to
re-start the ironic-conductor service
Note
You can find additional [sensor_data] and [metrics] options
in the Ironic sample config