Configuration¶
In order to use this mechanism driver the Neutron configuration file needs to be created/updated with the appropriate configuration information.
Each managed switch is configured as a section in the form
[genericswitch:<switch name>]. The device_type entry is mandatory and
determines which driver is used. Most other configuration entries are optional.
Note
Switch will be selected by local_link_connection/switch_info or ngs_mac_address. So, you can use the switch MAC address to identify switches if local_link_connection/switch_info is not set.
General configuration¶
The GenericSwitch mechanism driver needs to be enabled from
the ml2 config file /etc/neutron/plugins/ml2/ml2_conf.ini:
[ml2]
tenant_network_types = vlan
type_drivers = local,flat,vlan,gre,vxlan
mechanism_drivers = openvswitch,genericswitch
...
Physical networks need to be declared in the ML2 config as well, with a range
of VLANs that can be allocated to tenant networks. Several physical networks
can coexist, possibly with overlapping VLAN ranges: in that case, each switch
configuration needs to include its physical network, see Multiple physical networks.
Example of /etc/neutron/plugins/ml2/ml2_conf.ini with two physical networks:
[ml2_type_vlan]
network_vlan_ranges = physnet1:700:799,physnet2:600:850
For a given physical network, it is possible to specify several disjoint ranges of VLANs by simply repeating the physical network name multiple times:
[ml2_type_vlan]
network_vlan_ranges = physnet1:700:720,physnet1:750:760
If drivers support security groups then genericswitch_security_group can be appended
to the list of service_plugins (this also needs to be enabled per switch configuration):
[DEFAULT]
service_plugins = qos,ovn-router,trunk,segments,port_forwarding,log,genericswitch_security_group
(Re)start neutron-server specifying the additional configuration file
containing switch configuration:
neutron-server \
--config-file /etc/neutron/neutron.conf \
--config-file /etc/neutron/plugins/ml2/ml2_conf.ini \
--config-file /etc/neutron/plugins/ml2/ml2_conf_genericswitch.ini
For operational topics such as performance tuning, VXLAN L2VNI support, and advanced features, see the Administration Guide guide.
Switch configuration¶
These example device configuration snippets are assumed to be part of a
specific file /etc/neutron/plugins/ml2/ml2_conf_genericswitch.ini, but
they could also be added directly to /etc/neutron/plugins/ml2/ml2_conf.ini.
Netmiko (SSH/CLI) Devices¶
Switch configuration format:
[genericswitch:<switch name>]
device_type = <netmiko device type>
ngs_mac_address = <switch mac address>
ip = <IP address of switch>
port = <ssh port>
username = <credential username>
password = <credential password>
use_keys = <set to True when key_file is set>
key_file = <ssh key file>
secret = <enable secret>
ngs_allowed_vlans = <comma-separated list of allowed vlans for switch>
ngs_allowed_ports = <comma-separated list of allowed ports for switch>
Netmiko-specific NGS options:
ngs_batch_requests— ifTrue, batch concurrent switch requests into a single SSH session (default:False). Requires etcd coordination.ngs_ssh_disabled_algorithms— comma-separated list of<type>:<algorithm>entries to disable during SSH negotiation.ngs_ssh_connect_timeout— SSH connection timeout in seconds (default:60).ngs_ssh_connect_interval— interval between SSH connection retries in seconds (default:10).ngs_ssh_reuse_connection— ifTrue, reuse SSH connections across requests (default:False).
Examples¶
Here is an example for the Cisco 300 series device:
[genericswitch:sw-hostname]
device_type = netmiko_cisco_s300
ngs_mac_address = <switch mac address>
username = admin
password = password
ip = <switch mgmt ip address>
for the Cisco IOS device:
[genericswitch:sw-hostname]
device_type = netmiko_cisco_ios
ngs_mac_address = <switch mac address>
username = admin
password = password
secret = secret
ip = <switch mgmt ip address>
for the Cisco NX-OS device:
[genericswitch:sw-hostname]
device_type = netmiko_cisco_nxos
ngs_mac_address = <switch mac address>
# if security group support is required
ngs_security_groups_enabled = True
ip = <switch mgmt ip address>
username = admin
password = password
secret = secret
for the Huawei VRPV3 or VRPV5 device:
[genericswitch:sw-hostname]
device_type = netmiko_huawei
ngs_mac_address = <switch mac address>
username = admin
password = password
port = 8222
secret = secret
ip = <switch mgmt ip address>
for the Huawei VRPV8 device:
[genericswitch:sw-hostname]
device_type = netmiko_huawei_vrpv8
ngs_mac_address = <switch mac address>
username = admin
password = password
port = 8222
secret = secret
ip = <switch mgmt ip address>
for the Arista EOS device:
[genericswitch:arista-hostname]
device_type = netmiko_arista_eos
ngs_mac_address = <switch mac address>
ip = <switch mgmt ip address>
username = admin
key_file = /opt/data/arista_key
for the Dell Force10 device:
[genericswitch:dell-hostname]
device_type = netmiko_dell_force10
ngs_mac_address = <switch mac address>
ip = <switch mgmt ip address>
username = admin
password = password
secret = secret
for the Dell OS10 device:
[genericswitch:dell-hostname]
device_type = netmiko_dell_os10
ngs_mac_address = <switch mac address>
ip = <switch mgmt ip address>
username = admin
password = password
secret = secret
for the Dell PowerConnect device:
[genericswitch:dell-hostname]
device_type = netmiko_dell_powerconnect
ip = <switch mgmt ip address>
username = admin
password = password
secret = secret
# You can set ngs_switchport_mode according to switchmode you have set on
# the switch. The following options are supported: general, access. It
# will default to access mode if left unset. In general mode, the port
# be set to transmit untagged packets.
ngs_switchport_mode = access
Dell PowerConnect devices have been seen to have issues with multiple concurrent configuration sessions. See Synchronization and Batching for details on how to limit the number of concurrent active connections to each device.
for the Brocade FastIron (ICX) device:
[genericswitch:hostname-for-fast-iron]
device_type = netmiko_brocade_fastiron
ngs_mac_address = <switch mac address>
ip = <switch mgmt ip address>
username = admin
password = password
for the Ruijie device:
[genericswitch:sw-hostname]
device_type = netmiko_ruijie
ngs_mac_address = <switch mac address>
username = admin
password = password
secret = secret
ip = <switch mgmt ip address>
for the HPE 5900 Series device:
[genericswitch:sw-hostname]
device_type = netmiko_hp_comware
username = admin
password = password
ip = <switch mgmt ip address>
for the Juniper Junos OS device:
[genericswitch:hostname-for-juniper]
device_type = netmiko_juniper
ip = <switch mgmt ip address>
username = admin
password = password
ngs_commit_timeout = <optional commit timeout (seconds)>
ngs_commit_interval = <optional commit interval (seconds)>
for a Cumulus Linux device:
[genericswitch:hostname-for-cumulus]
device_type = netmiko_cumulus
ip = <switch mgmt_ip address>
username = admin
password = password
secret = secret
ngs_mac_address = <switch mac address>
for a Cumulus NVUE Linux device:
[genericswitch:hostname-for-cumulus]
device_type = netmiko_cumulus_nvue
ip = <switch mgmt_ip address>
username = admin
password = password
secret = secret
ngs_mac_address = <switch mac address>
for the Nokia SRL series device:
[genericswitch:sw-hostname]
device_type = netmiko_nokia_srl
username = admin
password = password
ip = <switch mgmt ip address>
for a Pluribus switch:
[genericswitch:sw-hostname]
device_type = netmiko_pluribus
username = admin
password = password
ip = <switch mgmt ip address>
for an ArubaOS-CX switch:
[genericswitch:aruba-hostname]
device_type = netmiko_aruba_aoscx
username = admin
password = password
ip = <switch mgmt ip address>
for the Supermicro device:
[genericswitch:sw-hostname]
device_type = netmiko_supermicro_smis
ngs_mac_address = <switch mac address>
ip = <switch mgmt ip address>
username = admin
password = password
secret = secret
NETCONF Devices¶
NETCONF devices use host (not ip) and connect via the NETCONF
protocol (port 830 by default). Connection parameters are passed directly
to ncclient.
Switch configuration format:
[genericswitch:<switch name>]
device_type = <netconf device type>
ngs_mac_address = <switch mac address>
ngs_physical_networks = <comma-separated list of physical networks>
host = <IP address or hostname of switch>
port = <NETCONF port, default 830>
username = <credential username>
password = <credential password>
key_filename = <ssh key file>
hostkey_verify = <true or false>
device_params = <ncclient device handler, e.g. name:nexus>
NETCONF-specific NGS options¶
ngs_openconfig_network_instance— OpenConfig network-instance for VLAN management (default:default).ngs_port_id_re_sub— JSON object withpatternandreplkeys for regex substitution on port IDs from LLDP. Example:{"pattern": "^Eth", "repl": "Ethernet"}ngs_openconfig_disabled_properties— comma-separated list of properties to omit from configuration payloads (e.g.port_mtu).ngs_netconf_target— force the NETCONF datastore target tocandidateorrunning. When unset (the default) the driver auto-detects from the server’s capabilities. Override this when the device’s candidate datastore is known to be unreliable.ngs_netconf_confirmed_commit— whether to use confirmed commit when the switch advertises the:confirmed-commitcapability (default:true). Set tofalseto skip the tentative commit entirely. This is useful for switches that hold their config backend busy for the full timeout window (e.g. Cisco NX-OS), blocking concurrent sessions.ngs_netconf_confirmed_commit_timeout— rollback timeout in seconds for the tentative confirmed commit, integer between 1 and 30 (default:5). Only used when confirmed commit is enabled and the switch advertises the capability. The confirming commit is sent immediately after the tentative commit, so a small value is usually sufficient.ngs_netconf_save_config— XML config payload sent viaedit-configto the running datastore to persist the configuration. Only used whenngs_save_configurationis enabled and the target datastore isrunning. Takes priority over the standardcopy-configto startup. See Configuration Persistence for vendor-specific examples.
Datastore Selection¶
The driver automatically detects which NETCONF datastore to use based on the capabilities advertised in the server’s hello message:
If the switch advertises the
:candidatecapability, the driver uses the candidate datastore with lock, discard, edit-config, validate, confirmed-commit, and commit.If only
:writable-runningis available, the driver edits the running datastore directly with lock and edit-config.
Set ngs_netconf_target to override auto-detection when the device’s
candidate datastore is known to be unreliable.
Configuration Persistence¶
When the target datastore is candidate, the commit operation implicitly
persists the configuration. When targeting the running datastore
directly, an additional step is needed to save the configuration to
non-volatile storage so it survives a reboot.
The driver attempts to persist the running configuration when
ngs_save_configuration is enabled, using the following priority:
Custom save config — if
ngs_netconf_save_configis configured, the driver sends it as anedit-configto the running datastore.copy-config to startup — if the device advertises the
:startupcapability, the driver performscopy-configfromrunningtostartup.Warning — if neither mechanism is available, the driver logs a warning that the configuration cannot be persisted.
Vendor examples for ngs_netconf_save_config:
Arista EOS (via the arista-cli YANG module):
ngs_netconf_save_config = <config><commands xmlns="http://arista.com/yang/cli"><command>write memory</command></commands></config>
Cisco IOS (via CLI config data):
ngs_netconf_save_config = <config><cli-config-data><cmd>write memory</cmd></cli-config-data></config>
Examples¶
For a NETCONF OpenConfig device:
[genericswitch:sw-hostname]
device_type = netconf_openconfig
ngs_mac_address = <switch mac address>
ngs_physical_networks = physnet1
ngs_trunk_ports = Ethernet1/48
ngs_disable_inactive_ports = True
ngs_port_default_vlan = 1
ngs_port_id_re_sub = {"pattern": "^Eth", "repl": "Ethernet"}
host = <switch mgmt ip address>
port = 830
username = admin
password = password
device_params = name:nexus
For an Arista EOS device via NETCONF (requires targeting the running datastore due to known candidate datastore issues):
[genericswitch:arista-hostname]
device_type = netconf_openconfig
ngs_mac_address = <switch mac address>
ngs_physical_networks = physnet1
ngs_trunk_ports = Ethernet1
ngs_netconf_target = running
ngs_save_configuration = true
ngs_netconf_save_config = <config><commands xmlns="http://arista.com/yang/cli"><command>write memory</command></commands></config>
host = <switch mgmt ip address>
username = admin
password = password