Überprüfen Sie die Verbindungsfähigkeit

Bevor Sie fortfahren, wird empfohlen, die Verbindung zum Internet und innerhalb der Knoten sicherzustellen.

  1. Testen Sie die Internetverbindung vom Knoten controller:

    # ping -c 4 docs.openstack.org
    PING files02.openstack.org (23.253.125.17) 56(84) bytes of data.
    64 bytes from files02.openstack.org (23.253.125.17): icmp_seq=1 ttl=43 time=125 ms
    64 bytes from files02.openstack.org (23.253.125.17): icmp_seq=2 ttl=43 time=125 ms
    64 bytes from files02.openstack.org (23.253.125.17): icmp_seq=3 ttl=43 time=125 ms
    64 bytes from files02.openstack.org (23.253.125.17): icmp_seq=4 ttl=43 time=125 ms
    
    
    --- files02.openstack.org ping statistics ---
    4 packets transmitted, 4 received, 0% packet loss, time 3004ms
    rtt min/avg/max/mdev = 125.192/125.282/125.399/0.441 ms
    
  2. Testen Sie die Verbindung vom Knoten controller zur Management-Schnittstelle des Knotens compute:

    # ping -c 4 compute1
    
    PING compute1 (10.0.0.31) 56(84) bytes of data.
    64 bytes from compute1 (10.0.0.31): icmp_seq=1 ttl=64 time=0.263 ms
    64 bytes from compute1 (10.0.0.31): icmp_seq=2 ttl=64 time=0.202 ms
    64 bytes from compute1 (10.0.0.31): icmp_seq=3 ttl=64 time=0.203 ms
    64 bytes from compute1 (10.0.0.31): icmp_seq=4 ttl=64 time=0.202 ms
    
    --- compute1 ping statistics ---
    4 packets transmitted, 4 received, 0% packet loss, time 3000ms
    rtt min/avg/max/mdev = 0.202/0.217/0.263/0.030 ms
    
  3. Testen Sie die Internetverbindung vom Knoten compute:

    # ping -c 4 openstack.org
    
    PING openstack.org (174.143.194.225) 56(84) bytes of data.
    64 bytes from 174.143.194.225: icmp_seq=1 ttl=54 time=18.3 ms
    64 bytes from 174.143.194.225: icmp_seq=2 ttl=54 time=17.5 ms
    64 bytes from 174.143.194.225: icmp_seq=3 ttl=54 time=17.5 ms
    64 bytes from 174.143.194.225: icmp_seq=4 ttl=54 time=17.4 ms
    
    --- openstack.org ping statistics ---
    4 packets transmitted, 4 received, 0% packet loss, time 3022ms
    rtt min/avg/max/mdev = 17.489/17.715/18.346/0.364 ms
    
  4. Testen Sie die Verbindung vom Knoten compute zur Management-Schnittstelle des Knotens controller:

    # ping -c 4 controller
    
    PING controller (10.0.0.11) 56(84) bytes of data.
    64 bytes from controller (10.0.0.11): icmp_seq=1 ttl=64 time=0.263 ms
    64 bytes from controller (10.0.0.11): icmp_seq=2 ttl=64 time=0.202 ms
    64 bytes from controller (10.0.0.11): icmp_seq=3 ttl=64 time=0.203 ms
    64 bytes from controller (10.0.0.11): icmp_seq=4 ttl=64 time=0.202 ms
    
    --- controller ping statistics ---
    4 packets transmitted, 4 received, 0% packet loss, time 3000ms
    rtt min/avg/max/mdev = 0.202/0.217/0.263/0.030 ms
    

Bemerkung

Red Hat und SUSE aktivieren standardmäßig eine restriktive Firewall. Bestimmte Schritte werden während der Installation fehlschlagen, sofern Sie die Firewall nicht ändern oder abschalten. Weitere Informationen zum Absichern Ihrer Umgebung finden Sie im OpenStack Security Guide.

Ubuntu aktiviert standardmäßig keine restriktive firewall. Für weitere Informationen zur Sicherung Ihrer Infrastruktur lesen Sie den OpenStack Security Guide.